Product Categories
-
Animal Monitoring & Life Support
-
Operating Theatre Equipment
-
Animal Diagnostic Laboratory
- Automatic Integrated Gene Detection System
- Hematology Analyzer
- Elisa Reader
- Chemistry Analyzer
- Blood Gas Electrolyte Analyzer
- Urine Analyzer
- Blood Gas&Immunoflurescence Analyzer
- Biological Safety Cabinet
- Biological Microscope
- Centrifuge
- Medical Pharmacy Refrigerator
- Blood Bank Refrigerator
- Combined Medical Refrigerator and Freezer
- Medical Freezer
- Laboratory Incubator
- Dry Oven
- Pet Rapid Test
-
Sterilizer (Autoclave)
-
Medical Imaging
-
Clinical Examination
-
Dental Equipment
-
Pet Grooming
product description
Introduction
ARI Vetcare delivery high precious veterinary anesthesia equipment system. It is suitable for animal hospital, pet clinic and animal laboratory. This technical index of animal anesthesia machine can meet the needs of general anesthesia and medical research on mice, dogs, cats, rabbits, monkeys, pigs, sheep, and other animals in animal laboratory.
Technical Specifications
PARAMETER |
SPECIFICATION |
Application |
0.5-100kg animal |
Ventilation mode |
Closed, half-closed, half-open |
Tidal volume |
10-2000ml |
Vaporizer |
Choose one from Isoflurane, Sevoflurane, Halothane |
Oxygen source pressure |
0.25~0.65Mpa |
Airway pressure scope |
030~60CMH2O |
Flow Control |
0-4L/min |
Oxygen Flush |
35L/min~75L/min |
Pop adjust scope |
Directs the waste anesthetic gas from the machine to a scavenging system. In the completely open position, the pop-off valve will release pressure at 2 cm H2O, while maintain a constant passive volume in the breathing bags. |
Inspiration impedance |
≦0.6Kpa |
Expiration impedance |
≦0.6Kpa |
Absorption tank capacity |
700ml |
Monitoring |
Airway pressure, Gas source pressure monitoring |
I:E |
As doctor need |
BPM |
As doctor need |
Configurations
Standard:Main unit, one anesthesia vaporizer, one set veterinary breathing circuit, one mobile trolley, breathing circuit, gas source hose, exhaust gas absorption system, corrugated connect pipeline, simulated lung.
Optional: Anesthesia ventilator (V-60V, V-80V), non-breathing circuit, tracheal intubation, anesthesia laryngoscope, soda lime, active carbon.
Anesthesia Ventilators (Optional)
Option 1: V-60V Anesthesia Ventilator
Pneumatically driven and electrically controlled
Display: LCD digital display
Animal Bellow: Big animal: 300-1500ML; Small animal: 0-300ML
Monitoring: Tidal volume, breathing rate, I:E ratio, peak airway pressure
TV: 0-300, 300-1600ml
Breathing rate: 2~150bpm
I:E ratio: Adjustable 3:1,2:1,1.5:1,1:1,1:1.5,1:2,1:3
Upper airway pressure:2~6kpa
Lower airway pressure:0.6~2kpa
Build in battery: work time more than 1 hour in case of power failure
Alarm: Battery low, Power failure, Airway pressure high/low
Alarm Silence: Manuel/Auto Switch
PIP scope: 5-60kpa
Option 2: V-80V Anesthesia Ventilator
Display: 9-inch TFT touch screen
Drive gas:
Gas type: O2 or Air
Inlet pressure: 280-600 kPa
Max flow: ≤120 L/min
Operating mode: VCV, PCV, SPONT, Manual, Demo
Waveform: Pressure, Flow-rate, Volume
Loop: PV loop, PF loop, FV loop
Safety pressure: System pressure does not exceed 6 KPa
Battery type: Li-ion, work time more than 2 hours
Tidal volume: 20 – 1500ml; Increment: 1ml
Respiratory rate: 1 ~ 100 bpm
Inspiratory time: 0.1 ~ 10s
Respiratory ratio: 9.9:1 to 1:9.9
Percentage of inspiratory pause: 0 to 50%
PEEP: OFF, 3 ~ 20 cmH2O
Pressure Support: 0 ~ 60 cmH2O
Pressure Control: 5 ~ 60 cmH2O
Flow trigger : 0.5 ~ 20L/min
Pressure Trigger Range: -1 ~ -20 cmH2O
PSV Insp Termination Level: 25%