Enquiry list 0

Product Categories

V-1200V1

Anesthesia Machine

product description

Introduction

ARI Vetcare delivery high precious veterinary anesthesia equipment system. It is suitable for animal hospital, pet clinic and animal laboratory. This technical index of animal anesthesia machine can meet the needs of general anesthesia and medical research on mice, dogs, cats, rabbits, monkeys, pigs, sheep, and other animals in animal laboratory.

 

Technical Specifications

PARAMETER

SPECIFICATION

Application

0.5-100kg animal

Ventilation mode

Closed, half-closed, half-open

Tidal volume

10-2000ml

Vaporizer

Choose one from Isoflurane, Sevoflurane, Halothane

Oxygen source pressure

0.25~0.65Mpa

Airway pressure scope

030~60CMH2O

Flow Control

0-4L/min

Oxygen Flush

35L/min~75L/min

Pop adjust scope

Directs the waste anesthetic gas from the machine to a scavenging system. In the completely open position, the pop-off valve will release pressure at 2 cm H2O, while maintain a constant passive volume in the breathing bags.

Inspiration impedance

≦0.6Kpa

Expiration impedance

≦0.6Kpa

Absorption tank capacity

700ml

Monitoring

Airway pressure, Gas source pressure monitoring

I:E

As doctor need

BPM

As doctor need

 

Configurations

Standard:Main unit, one anesthesia vaporizer, one set veterinary breathing circuit, one mobile trolley, breathing circuit, gas source hose, exhaust gas absorption system, corrugated connect pipeline, simulated lung.

Optional: Anesthesia ventilator (V-60V, V-80V),  non-breathing circuit, tracheal intubation, anesthesia laryngoscope, soda lime, active carbon.

 

Anesthesia Ventilators (Optional)

Option 1: V-60V Anesthesia Ventilator

Pneumatically driven and electrically controlled

Display: LCD digital display

Animal Bellow: Big animal: 300-1500ML; Small animal: 0-300ML

Monitoring: Tidal volume, breathing rate, I:E ratio, peak airway pressure

TV: 0-300, 300-1600ml

Breathing rate: 2~150bpm

I:E ratio: Adjustable 3:1,2:1,1.5:1,1:1,1:1.5,1:2,1:3

Upper airway pressure:2~6kpa

Lower airway pressure:0.6~2kpa

Build in battery: work time more than 1 hour in case of power failure

Alarm: Battery low, Power failure, Airway pressure high/low

Alarm Silence: Manuel/Auto Switch

PIP scope: 5-60kpa

 

Option 2: V-80V Anesthesia Ventilator

Display: 9-inch TFT touch screen

Drive gas:

Gas type: O2 or Air

Inlet pressure: 280-600 kPa

Max flow: ≤120 L/min

Operating mode: VCV, PCV, SPONT, Manual, Demo

Waveform: Pressure, Flow-rate, Volume

Loop: PV loop, PF loop, FV loop

Safety pressure: System pressure does not exceed 6 KPa

Battery type: Li-ion, work time more than 2 hours

Tidal volume: 20 – 1500ml; Increment: 1ml

Respiratory rate: 1 ~ 100 bpm

Inspiratory time: 0.1 ~ 10s

Respiratory ratio: 9.9:1 to 1:9.9

Percentage of inspiratory pause: 0 to 50%

PEEP: OFF, 3 ~ 20 cmH2O

Pressure Support: 0 ~ 60 cmH2O

Pressure Control: 5 ~ 60 cmH2O

Flow trigger : 0.5 ~ 20L/min

Pressure Trigger Range: -1 ~ -20 cmH2O

PSV Insp Termination Level: 25%

related products