product description
Introduction
Meet various requirements of surgical scenarios for animal, including thoracotomy, diaphragmatic hernia, or- thopedics, minimally invasive surgery, etc.
Features
-9 inch touch screen,responsive and one-button switch
-Powerful turbine driven,no gas requred for ventilator
-VCV,PCV,SPONT,and MANUAL SIMV, CPAP/PSV,PRVC,SIMV-PC,SIMV-PRVC mode,
tidal volume monitoring as low as 3ML
-CGO/ACGO one key switch
-EtCO2 Monitoring
-FIO2 monitor oxygen concentration
-Various type oxygen concentrator can be put (optional)
-High precision vaporizer,stable anesthesia output concentration
Technical Specifications
PARAMETER |
SPECIFICATION |
Main unit |
|
Work mode |
Cycle breathing;non-breathing |
Application range |
Animal weight 0.8-120kg |
Oxygen flush |
25L/min-75L/min |
Trolley |
High quality aluminum |
CO2 absorber |
|
1) Integrated design of animal-specific integrated bellows and absorbe |
|
2) Dedicated fresh gas connection to non-breathing circuit |
|
3) Visible inspiration and expiration valve design to observe the breathing state easy |
|
4) Professional active pressure release valve design, it is connected to the exhaust gas recovery system, and provides continuous 2cmH20 nega-tive pressure for airbag |
|
5) Airway pressure real-time monitoring |
|
6) Quick change soda lime canister design |
|
7) Strong air tightness and reduced airway resistance |
|
Flowmeter |
|
Animal-specific oxygen 2 tube |
|
Flow |
0~1&1-10L/min |
O2 and Air |
O2 flow:0-10L/min |
Air flow:0-10L/min |
|
Ventilator |
|
Drive mode |
Turbine and electronic control |
Bellow |
0-300ML; 0-1500ML |
Waveform |
pressure, flow, volume, end expira-tory |
Loop |
pressure-volume; pressure-flow; flow-volume |
Tidal volume |
machine control: 3-1600ml |
Manual:5-1600ml |
|
Breathing rate |
1~100bpm |
I:E |
9.9:1 to 1:9.9 |
Inhalation time |
0.1~10.0s |
Inspiratory pause% |
0-50% |
PEEP |
OFF, 3~20 cmH2O |
Pressure support |
0~60 cmH2O |
Pressure control |
5~60 cmH2O |
Flow rate trigger |
0.5~20L/min |
Pressure trigger |
-1~-20 cmH2O |
PSV inspiratory terminal level |
25% |
Anesthesia vaporizer |
|
With pressure, flow and temperature automatic compensation |
|
Concentration range |
lsoflurane: 0.2-5% |
Sevoflurane |
0.2-8% |
Halothane |
0.2-5% |
Flow rate range |
0.2-15L/min |
Monitor paramter |
|
Inspiratory/expiratory tidal volume, breathing rate, spontaneous breathing rate, I:E ratio,driving gas pressure, spontaneous ventilation volume, minute ventilation, peak/airway/mean airway pressure/ PEEP end-tidal pressure, inspi- ratory plateau pressure FIO2, ETCO2 |
|
Alarm parameters |
|
Tidal volume, minute ventilation, breathing rate, airway pressure, peak airway pressure,apena alarm, gas supply pressure failure alarm, power supply alarm, pipeline detachment or air leakage, low air gas pressure, PEEP end-tid-al pressure, FIO2, FiCO2 |