VC-U60

Portable Veterinary Color Doppler Ultrasound Scanner

product description

Features

  • Applicable for animals’ examination and diagnosis on digestive system, reproductive system, urinary system for animal hospitals and scientific institutions.
  • 15 inch high resolution medical LCD monitor.
  • Anatomic M Mode Imaging (Sampling line≥ 3).
  • Contrast Tuned Imaging.
  • Tissue Harmonic Imaging (THI).
  • B/C/D Real-time three synchronous imaging.
  • Color Doppler Imaging (CFM, PDI, DPDI).
  • Spectral Doppler Imaging (PW, HPRF PW, CW).
  • Support: Chinese/ English/ Spanish/ French/ Russian.
  • Space compound imaging (application to Abdominal, GYN, vessel, superficial small organs, can be dual image contrast display at same time).

 

Technical Specifications

PARAMETER

SPECIFICATION

2D Imaging Mode

Receiving mode

transmitting and receiving channel ≥1024, multi-signal parallel processing

Line density

≥512, visible and adjustable

TGC

8 segment adjustable

Gain

B / M / D separately adjustable, ≥100dB

Dynamic range

≥180dB

Max scanning depth

≥360mm

Grey scale

0-67, visible and adjustable

Sound power

1%-100%

Full Digital Beamformers

Linear array probe two-dimensional independent deflection

ZoomPIP (1.5 / 2.0 / 2.5 / 3.0 / 3.5 / 4.0 / 4.5 / 5.0 / 10 times)

Digital full dynamic focusing, digital variable aperture and dynamic trace change, A/D≥15 bit

Color Doppler Imaging Mode

Imaging

including velocity, velocity variance, energy, direction energy display, etc

Display mode

B/C, B/C/M, B/POWER, B/C/PW

Line density

≥3 level

Color hiding technology

without back to B mode can hide C mode, only color speed ruler display

Blood flow graph, color flow profile to measure intravascular velocity

Spectral Doppler Imaging Mode

Display

full screen, duplex / triplex (PW only)

Gain

≥100dB

Velocity

≥4 level adjustable

Max scanning speed

PWD: Positive or negative blood flow velocity≥7.6m/s;

CWD: blood flow velocity ≥20.0m/s, min ≤5 mm/s (Nonnoise signal)

Display mode

B, PW, B/PW, B/C/PW, B/CW, B/C/CW, etc

Display control

reverse, zero shift, B refresh, D extension, B/D extension, etc

Smart Doppler technology

freely switch between real-time B+CFM mode and real-time PW mode

Zero shift adjustable ≥8 level

Automatic Spectrum Measurement, Manual Measurement

PView Wide Field Imaging

High-resolution display, length can up to 50cm

Imaging support forward erasure, no need to re-imaging

With two dimensional wide view imaging mode and color wide view imaging mode

 

 

Various Probes

Wideband with frequency conversion, independent frequency conversion under B and CFM.

 

  • Convex probe

Fundamental Frequency: 2.0MHz/ 2.3MHz/ 2.5MHz/ 3.0MHz/ 3.5MHz/ 4.0MHz/ 4.6MHz/ 5.0MHz/ 5.4MHz (9 levels frequency conversion)

    Harmonic Frequency: 4.0MHz/ 4.6MHz/ 5.0MHz (3 levels frequency conversion)

 

  • Linear probe

Fundamental Frequency: 4.0MHz/ 4.6MHz/ 5.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz/ 9.2MHz/ 10.0MHz/ 12.0MHz/ 13.3MHz (9 levels frequency conversion)

Harmonic Frequency: 8.0MHz/ 9.2MHz/ 10.0MHz (3 levels frequency conversion)

 

  • Micro-convex probe

Fundamental Frequency: 3.0MHz/ 3.5MHz/ 4.0MHz/ 5.0MHz/ 5.4MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz (8 levels frequency conversion)

Harmonic Frequency: 6.0MHz/ 7.0MHz/ 8.0MHz (3 levels frequency conversion)

 

  • Phased array probe

Fundamental Frequency: 1.7MHz/ 1.9MHz/ 2.1MHz/ 2.5MHz/ 3.0MHz/ 3.4MHz/ 3.8MHz/ 4.2MHz/ 5.0MHz (9 levels frequency conversion)

Harmonic Frequency: 3.4MHz/ 3.8MHz/ 4.2MHz (3 levels frequency conversion)

 

  • High frequency phased array probe

Fundamental Frequency: 3.0MHz/ 3.5MHz/ 4MHz/ 5MHz/ 5.4MHz/ 6MHz/ 7MHz/ 8MHz (9 levels frequency conversion)

Harmonic Frequency: 6MHz/ 7MHz/ 8MHz (3 levels frequency conversion)

 

  • Technical requirements for electronic convex probe

Frequency: 2.0-5.4 MHz, lateral resolution: ≤2 (depth≤80), ≤3mm (80<depth≤130)

Axial resolution: ≤1 (depth≤80), ≤1mm (80<depth≤130)

Dead zone: ≤3mm; Geometric position accuracy: broadwise: ≤5%; lengthwise:≤5%

Detecting depth≧240mm

 

  • Technical requirements for electronic linear probe

Frequency: 4.0-13.3MHz, lateral resolution: ≤1 (depth ≤40),

Axial resolution: ≤0.5 (depth ≤50),

Dead zone: ≤3mm; Geometric position accuracy: broadwise: ≤4%; lengthwise: ≤2%

Detecting depth ≧100mm